T75 Innovative Sensors, Technologies and Strategies for Performance Monitoring of Waste Disposal Facilities and Remediation Approaches
Monday, 23 October 2006
8:00 AM - 12:00 PM
PUMPING MONITOR WELLS FOR EARLY DETECTION MONITORING AT NUCLEAR FACILITIES
Paper number: T75-13
Program: Technical Sessions
Time: 10:55 AM – 11:10 AM
Authors
-
Van PriceUniv of South Carolina, Columbia, SC
-
Thomas J. NicholsonU.S. Nuclear Regulatory Commission, Rockville, MD
Abstract
An active system that continuously pumps water from one or more monitor wells near the facility is proposed and evaluated with modeling. A pumping monitor well creates a large capture zone, both vertically and horizontally, increasing the likelihood of capture and detection. The principal contaminants of concern at nuclear facilities are radionuclides, which can be detected at low concentrations, minimizing the concern of dilution due to pumping. Early detection of mobile contaminants through pumping could allow problems to be identified and mitigated, minimizing efforts associated with remediating a large plume of multiple contaminants. The benefit of an active system is demonstrated by modeling results of a tritium plume emanating from the high flux beam reactor (HFBR) at Brookhaven National Laboratory.