T271 Characterizing, Predicting, and Managing Long-Term Contaminant Flux for Complex Subsurface Environments
Wednesday, 21 October 2009
1:30 PM - 5:30 PM
E141/142
MASS BALANCE ASPECTS OF PERSISTENT URANIUM CONTAMINATION IN THE SUBSURFACE AT THE HANFORD SITE, WASHINGTON
Paper number: T271-9
Program: Technical Sessions
Time: 3:30 PM – 3:45 PM
Authors
-
Christopher F. BrownPacific Northwest National Laboratory, Richland, WA
-
R. Jeffrey SernePacific Northwest National Laboratory, Richland, WA
Abstract
Estimates have also been developed for the inventory of contaminant uranium in various subsurface regions, using sediment and water samples that cover the vadose zone, the zone through which the water table rises and falls, and the uppermost hydrologic unit within the unconfined aquifer. The largest inventory is associated with the vadose zone beneath former disposal facilities and may reach several thousand kilograms, which is a relatively small fraction of the amount historically disposed. Contamination is concentrated in the vadose zone beneath former disposal facilities, but may also be widespread in sediment through which the water table has fluctuated, especially during earlier 300 Area operating conditions. How much of the inventory is available for migration under current conditions to resupply the groundwater plume is a principal uncertainty in the conceptual model. However, as mass balance estimates for the plume become more refined and defensible with field data, limits can be placed on the resupply via downward migration from the vadose zone, thus providing key information for evaluating remediation alternatives.