T194 Applications of Structural Geology in Meeting the Natural Resource and Energy Needs of Society: Challenges and Innovations for the Twenty-First Century (Posters)
Tuesday, 2 November 2010
8:00 AM - 6:00 PM
Hall D
COMBINED FLUID INCLUSION--SEM CATHODOLUMINESCENCE ANALYSIS OF MICROFRACTURE OPENING IN A TIGHT-GAS SANDSTONE OUTCROP ANALOG: ERIBOLL FORMATION, NW SCOTLAND
Paper number: T194-3
Program: Technical Sessions
Time: 8:00 AM – 6:00 PM
Authors
-
Guangjian Xu Presenting AuthorJackson School of Geosciences, The University of Texas at Austin, Austin, TX
-
András FallThe University of Texas at Austin, Austin, TX
-
Peter EichhublThe Univ of Texas at Austin, Austin, TX
-
Stephen LaubachThe University of Texas at Austin, Austin, TX
Abstract
Previous fluid inclusion measurements on macrofractures were obtained before SEM-cathodoluminescence imaging to avoid possible damage of inclusions during imaging. To aid the textural interpretation of microfractures during fluid inclusion microthermometry, we systematically tested the effect of SEM beam damage by measuring homogenization temperatures of fluid inclusions of varying depth within multiple samples before and after cathodoluminescence imaging. We found that beam damage is noticeable only within the uppermost 5-10 µm of the sample, resulting in leaked inclusions. Below this zone, repeat measurements of fluid inclusion homogenization temperatures after CL imaging are within 1°C , demonstrating that beam damage in our samples is negligible below the topmost layer of the sample, thus allowing SEM-cathodoluminescence imaging prior to fluid inclusion microthermometry.