CHOOSING THE RIGHT FIELD METHODS TO OBTAIN TRUE IN SITU TDGP
Paper number: T37-6
Program: Technical Sessions
Time: 9:00 AM – 6:00 PM
Authors
-
J. RandellUniversity of Calgary, Calgary, AB
-
James W. RoyEnvironment Canada, Burlington, ON
Abstract
There are currently two approaches to estimating in situ TDGP. 1. Productive wells can be purged without significant drawdown. In this case TDGP is measured at the screen during low-flow purging until an equilibrium value is reached. 2. TDGP measurement in wells that cannot be purged without significant drawdown (common on the prairies) is more tractably obtained by isolating groundwater at the well screen and measuring downhole TDGP until an equilibrium value is obtained. Both of these approaches can be adopted for temporal data collection. The choice of field method can also depend on water table depth and the pumping approaches available, and whether one wants to avoid pumping contaminated groundwater.
Since equilibration times can vary depending on the type of groundwater gas(es) and between TDGP probes, data showing the variation in calibration times are presented.