54 Environmental Geoscience (Posters)
Monday, 24 March 2014
1:30 PM - 5:35 PM
Freedom Hall A
STREAM WATER-QUALITY MONITORING ON THE SOUTHERN EDGE OF THE LAKE ERIE DRAINAGE BASIN, PENNSYLVANIA, USA
Paper number: 54-5
Program: Technical Sessions
Time: 1:30 PM – 5:35 PM
Authors
-
Kathryn SaukaSchool of Science, Erie, PA
-
Anthony M. FoylePenn State Erie - The Behrend College, Erie, PA
-
Michael W. JustikPenn State Erie - The Behrend College, Erie, PA
Abstract
In the field, a La Motte Pocket Tester was used to measure salinity, conductivity, TDS, and temperature; pH test strips were used to determine pH; a flow meter was used to determine water velocity and stream cross sections were surveyed using a tape and rod. In the laboratory, 1.5 liter samples of stream water were rotary-evaporated to concentrate samples; liquid-liquid extraction was used to remove the organic compounds; and a Gas Chromatograph-Mass Spectrometer was used to identify and determine the concentration of organic compounds present. From fall 2012 to fall 2013, the water-quality of streams decreased slightly as levels of total dissolved solids and organic compounds increased. Some of the organic compounds found were common components in fuel, paint thinners, and soap. The pH of both streams remained stable (between 6.5 and 7.5), and the stream temperatures and discharges showed no significant changes over the course of the observation period.