T107 Sources, Transport, Fate, and Toxicology of Trace Elements and Organics in the Environment (Posters)
Monday, 2 November 2015
9:00 AM - 6:30 PM
Exhibit Hall
IMAGING THE IN SITU REDUCTION OF CHROMIUM(VI) ON MAGNETITE SURFACES USING ELECTROCHEMICAL AFM
Paper number: T107-12
Program: Technical Sessions
Time: 9:00 AM – 6:30 PM
Authors
-
Maria C. MarcanoUniversity of Michigan, Ann Arbor, MI
-
Will M. BenderUniversity of Michigan, Ann Arbor, MI
-
Udo BeckerUniversity of Michigan, Ann Arbor, MI
Abstract
Batch experiments were also performed on the same samples used in the AFM. Here, changes in the Cr concentration in solution were monitored using inductively-coupled mass spectrometry (ICP-MS). At pH 3, more Cr is removed from solution (~35% after 45 min., starting at 2 µM Cr(VI)) at high positive as well as negative potentials. XPS analyses of the magnetite surface suggest that only Cr(III) phases are present and that Cr and/or Fe-Cr oxide phases are more stable at very reducing conditions (–0.75 V), while Cr/Fe-Cr (oxy)hydroxide phases are present under more moderately reducing conditions (–0.25 V). These oxyhydroxide phases are very soluble below pH 5, which explains why there is little decrease in Cr from solution at intermediate potentials. Although some precipitation is observed at pH 11, less than 7% of the total Cr was removed from solution after 45 minutes. Fe(II)/Fe(III) ratios calculated from XPS analyses (0.33), however, are lower than the expected ratio of magnetite. This oxidized layer, possibly maghemite (γ-Fe2O3) or FeOOH, may inhibit the reduction of Cr(VI) on the surface.