T113 Advances in Groundwater Modeling (Posters)
Monday, 2 November 2015
9:00 AM - 6:30 PM
Exhibit Hall
FLUID FLOW AND HEAT TRANSPORT IN A BOREHOLE THERMAL ENERGY STORAGE SYSTEM
Paper number: T113-9
Program: Technical Sessions
Time: 9:00 AM – 6:30 PM
Authors
-
Shemin GeUniversity of Colorado, Boulder, CO
-
John S. McCartneyUniversity of California-San Diego, La Jolla, CA
Abstract
Measured time-dependent injection temperatures and fluid circulation rates at the Drake Landing Solar Community are used as model inputs. The model is calibrated using measured soil temperature time series. The simulated and measured temperatures agree well with an intrinsic permeability of 1.5×10-14 m2, thermal conductivity of 2.0 W/m°C, and a volumetric heat capacity of 2.3 MJ/m3 °C. The calibrated model serves as the basis for a sensitivity analysis of soil thermal and hydrological parameters on BTES system heat extraction efficiency. Sensitivity analysis results suggest that: 1) BTES heat extraction efficiency increases with decreasing soil thermal conductivity; 2) BTES efficiency decreases with background groundwater flow; 3) BTES heat extraction efficiency decreases with convective heat losses associated with high soil permeability values; and 4) unsaturated soils show higher overall heat extraction efficiency due to convection onset at higher intrinsic permeability values.