T170 Fate, Effects, and Mitigation of Chemical and Fuel Releases in Surface and Subsurface Environments (Posters)

Monday, 23 October 2017
9:00 AM - 6:30 PM
Halls 4EF


CHARACTERIZING DNAPL CONTAMINATION AND VAPOR INTRUSION IN DAYTON, OHIO

Paper number: T170-5
Program: Technical Sessions
Time: 9:00 AM – 6:30 PM


Authors


Abstract

Vapor intrusion originating from volatile organic compounds (VOCs) represents a growing concern for toxic chemical exposure to the public. A former manufacturing site in Dayton, Ohio has experienced soil and groundwater contamination due to leakage from underground storage tanks containing trichloroethylene (TCE), perchloroethylene (PCE), and chloroform. Increased levels of VOC vapor concentrations were detected in the vicinity of the site leading to an investigation by the Ohio EPA and US EPA. For this study, geologic well-log, hydraulic head, and contaminant (TCE, PCE, chloroform) concentration data obtained at 13 groundwater monitoring wells were analyzed to characterize geologic and hydrogeologic settings of the aquifer, and patterns of groundwater flow and contaminant migration within the contaminated aquifer were also derived using this information. In addition, 24 soil samples and 30 soil vapor data collected throughout the study area were analyzed to characterize distributions of organic vapor in the unsaturated zone.

The study site is underlain by an approximately three-meter thick layer of unsaturated sand and gravel layer above the primary aquifer (comprised of sand and gravel) separated by a meter-thick layer of clay. Primary direction for groundwater flow and contaminant migration in the sand and gravel aquifer is to the southeast towards a river where other residences are located. The VOC contamination is most severe where three of the former underground storage tanks were located with soil vapor concentrations of up to 8,100 ppbv (parts per billion per volume of air) of chloroform and 7,700 ppbv of TCE. Dissolved concentrations in groundwater samples were as high as 370 μg/L for chloroform and 150 μg/L for PCE. Results of this study may provide insight into further developing mechanisms in identifying vapor intrusion in residential homes resulting from sub-surface contaminant sources.


Geological Society of America Abstracts with Programs. Vol. 49, No. 6

doi: 10.1130/abs/2017AM-303637

© Copyright 2017 The Geological Society of America (GSA), all rights reserved. Permission is hereby granted to the author(s) of this abstract to reproduce and distribute it freely, for noncommercial purposes. Permission is hereby granted to any individual scientist to download a single copy of this electronic file and reproduce up to 20 paper copies for noncommercial purposes advancing science and education, including classroom use, providing all reproductions include the complete content shown here, including the author information. All other forms of reproduction and/or transmittal are prohibited without written permission from GSA Copyright Permissions.