T226 Best Practices and Exciting Discoveries in Identifying, Mapping, and Analyzing Planetary Landforms and Terrestrial Analogues
Wednesday, 12 October 2022
8:00 AM - 12:00 PM
501
PROSPECTING FOR MARTIAN SULFIDE ORE DEPOSITS USING THERMAL-INFRARED EMISSION SPECTROSCOPY
Paper number: T226-3
Program: Technical Sessions
Time: 8:20 AM – 8:35 AM
Authors
-
Christopher HaberleSchool of Earth and Space Exploration, Arizona State University, Tempe, AZ
-
Linda T. Elkins-TantonArizona State University, Tempe, AZ
-
Philip R. ChristensenArizona State University, Tempe, AZ
Abstract
Thermal-infrared emission measurements of two suites of physically constructed 500-710 μm silicate/sulfide mixtures were acquired from 2000–250 cm-1 (5–40 μm) using a Nicolet iS50 FTIR modified for emission. Emissivity spectra were calibrated using the conventional calibration method used in remote sensing applications and a new reference calibration method developed specifically for low-emissivity materials such as pyrrhotite. Our results suggest that several indicator variables can be used in tandem to prospect for extraterrestrial sulfide deposits, including: (1) the apparent brightness temperature, (2) the appearance of a negative slope from high to low wavenumbers in the emissivity spectrum calibrated using the conventional calibration routine, (3) a decrease in the emissivity value at the Christiansen Frequency of the silicate endmember when calibrated using the reference temperature method, and (4) a lack of transparency features in “intraband” regions of the spectrum coupled with (5) a reduction in spectral contrast at the Reststrahlen Bands and other spectral absorptions of the silicate component. The deconvolution results confirm that linear mixing is a valid assumption for infrared emission spectra containing a spectrally featureless component.
Additionally, a spectral deconvolution technique was applied to each mixture spectrum to determine if the abundance of sulfide in our physically constructed mixtures could be accurately predicted. The spectroscopically determined modal abundance of sulfide is within ~12 ± 7 vol % of the measured abundances using the conventional calibration technique and ~6 ± 4 vol % when using the reference temperature calibration technique. Regardless of the calibration method, the detectability limit is ~10% for the sulfide endmember.
Geological Society of America Abstracts with Programs. Vol. 54, No. 6
doi: 10.1130/abs/2022AM-379260
© Copyright 2022 The Geological Society of America (GSA), all rights reserved. Permission is hereby granted to the author(s) of this abstract to reproduce and distribute it freely, for noncommercial purposes. Permission is hereby granted to any individual scientist to download a single copy of this electronic file and reproduce up to 20 paper copies for noncommercial purposes advancing science and education, including classroom use, providing all reproductions include the complete content shown here, including the author information. All other forms of reproduction and/or transmittal are prohibited without written permission from GSA Copyright Permissions.