12 Recent Advances in PFAS and Emerging Contaminant Science: From Human Health Risk Assessment to Fate and Transport

Sunday, 17 March 2024
1:30 PM - 5:30 PM
Merrimack Room


SITE INVESTIGATION OF A PFAS-IMPACTED FIREFIGHTER TRAINING FACILITY IN SOUTHWEST VERMONT

Paper number: 12-9
Program: Theme Sessions
Time: 3:50 PM – 4:10 PM


Authors


Abstract

The State-owned Vermont Fire Academy, located in southwest Vermont, used aqueous film-forming foams (AFFF) for firefighter training from the 1990s until 2011 when a fluorine-free training foam was introduced. In 2016 a release of per- and polyfluoroalkyl substances (PFAS), primarily perfluorooctanesulfonic acid (PFOS), was identified in near-surface soils. Subsequent investigation beginning in 2020 identified a PFAS-contaminated vadose zone up to 30 meters thick comprised of glaciolacustrine sand and gravel overlying basal till interpreted as a kame terrace. The site is underlain by Neoproterozoic-lower Cambrian metawackes and dolostones of the Pinnacle Formation (CZpw) and Forestdale Formation (CZfd), respectively. On-going investigation activities are focused on 1) potentially impacted drinking water and/or surface water receptors, and 2) defining the extent of impacted groundwater with the goal of supporting a groundwater reclassification pursuant to the Vermont Groundwater Protection Rule and Strategy. Additional site features include a large PFAS-contaminated concrete training pad and underground concrete water reclaim tank used to support firefighter training events. The training grounds are served by municipal water unimpacted by PFAS; however, the training activities require the capture of meteoric water for use in training purposes under the site’s Act 250 Land Use Permit first issued in 1988. The water reclaim tank was historically discharged to the ground surface and has included a permanent effluent treatment system since 2020 utilizing granular activated carbon. Soil and groundwater investigations are being conducted by the Vermont Department of Buildings and General Services under the oversight of the Vermont Department of Environmental Conservation, with geophysical (Tromino™ passive seismic) and detailed structural mapping data provided by the Vermont Geological Survey. The latest conceptual site model will be shared along with challenges related to the site geology and release mechanisms.

Geological Society of America Abstracts with Programs. Vol. 56, No. 1

doi: 10.1130/abs/2024NE-397642

© Copyright 2024 The Geological Society of America (GSA), all rights reserved. Permission is hereby granted to the author(s) of this abstract to reproduce and distribute it freely, for noncommercial purposes. Permission is hereby granted to any individual scientist to download a single copy of this electronic file and reproduce up to 20 paper copies for noncommercial purposes advancing science and education, including classroom use, providing all reproductions include the complete content shown here, including the author information. All other forms of reproduction and/or transmittal are prohibited without written permission from GSA Copyright Permissions.