T36 New Advances and Applications of CA-TIMS U/Pb Geochronology and CA Method in the Earth Sciences: A Session in Honor of James Mattinson (Posters)
Sunday, 22 September 2024
8:00 AM - 5:30 PM
Hall D
INCREASED ACCURACY OF MAXIMUM DEPOSITIONAL AGE (MDA) ESTIMATIONS USING CHEMICAL ABRASION-LASER ABLATION-INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (CA-LA-ICPMS)
Paper number: T36-4
Program: Technical Sessions
Time: 8:00 AM – 5:30 PM
Authors
-
Michael EddyPurdue University, West Lafayette, IN
-
Mauricio Ibanez-MejiaUniversity of Arizona, Tucson, AZ
Abstract
Recent work by Donaghy et al. (2024) shows that bulk CA of detrital zircon aliquots prior to LA-ICPMS improves the accuracy of detrital zircon spectra by selectively removing zircon domains affected by Pb-loss. We build on this study by analyzing CA-treated (N=2; n=569) and untreated aliquots (N=2; n=594) of two Eocene detrital zircon samples (SK2-535 and MT1-214) to assess the impact CA has on the accuracy of MDA estimations. Treated and untreated aliquots were first analyzed using LA-ICPMS to identify and compare peak age populations, followed by plucking of the youngest zircons in each aliquot to be tandem dated using CA-ID-TIMS. The youngest zircons from an additional CA-treated Eocene detrital zircon sample were also tandem dated.
All zircon tandem dated from CA-treated aliquots (N=3; n=14) yielded CA-LA-ICPMS dates that overlap within 2σ of their respective CA-ID-TIMS dates. We found the CA-LAICPMS dates to be between 0.6-3.6% younger than their respective CA-ID-TIMS dates, approaching the limits of single-spot precision by LA-ICPMS. In contrast, only one zircon from the untreated aliquots (N=2; n=6) overlapped within 2σ uncertainty of its CA-ID-TIMS date. The average negative bias of untreated LA-ICPMS dates was variable by sample, with most analyses between 4.5-5.8% younger than the CA-ID-TIMS dates. One zircon had a LA-ICPMS date 15.9% younger than its CA-ID-TIMS date, equating to an ~10 Myr difference. These results support the notion that Pb-loss can have a substantial effect on the accuracy of estimated MDAs, even for young samples and regardless of the method used for MDA calculation. We suggest CA-LA-ICPMS could be an important technique to mitigate the negative effects of Pb-loss and significantly improve the accuracy of MDA estimations.
Geological Society of America Abstracts with Programs. Vol. 56, No. 5
doi: 10.1130/abs/2024AM-401907
© Copyright 2024 The Geological Society of America (GSA), all rights reserved. Permission is hereby granted to the author(s) of this abstract to reproduce and distribute it freely, for noncommercial purposes. Permission is hereby granted to any individual scientist to download a single copy of this electronic file and reproduce up to 20 paper copies for noncommercial purposes advancing science and education, including classroom use, providing all reproductions include the complete content shown here, including the author information. All other forms of reproduction and/or transmittal are prohibited without written permission from GSA Copyright Permissions.