9 Environmental Hydrogeology and Geochemistry
Tuesday, 1 May 2001
8:00 AM - 12:00 PM
SITE SPECIFIC SEPTIC TANK SOIL-ABSORPTION SYSTEM DENSITY/LOT-SIZE RECOMMENDATIONS, CEDAR VALLEY, SOUTHWESTERN UTAH
Paper number: 9-1
Program: Technical Sessions
Time: 10:30 AM – 10:45 AM
Authors
-
Mike LoweSalt Lake City, UT
-
Charles E. BishopSalt Lake City, UT
Abstract
Calculations show (assuming a degradation limit of 1 mg/L in water quality from nitrate) recommended average lot size on an alluvial-fan recharge-area development in southwestern Cedar Valley may be as small as 5.6 acres, while in the drier western part of the basin located in a secondary recharge area, average lot size should be no smaller than 54 acres. In the basin center, a possible discharge area, the amount of effluent water produced from existing septic systems exceeds the amount of natural ground-water flow in the aquifer available for mixing. Because of this condition and an apparent upward vertical-head gradient in the area, we believe the mass-balance approach is not the best land-use management tool, and recommend managing ground-water withdrawals to maintain the upward gradient; relatively thick, continuous clay layers that are prevalent in this area produce confined conditions that may protect the aquifer from contamination associated with septic systems.