T193 Water, Solute, and Sediment Fluxes through Carbonate and Karst Aquifers (Posters)
EFFECTIVE POROSITY, STORAGE, AND GROUND-WATER SIMULATION IN THE TRIPLE-POROSITY, KARSTIC BISCAYNE AQUIFER, SE FLORIDA, USA
Paper number: T193-1
Program: Technical Sessions
Time: 1:30 PM – 5:30 PM
Authors
-
Robert A. RenkenFt. Lauderdale, FL
-
Barclay W. ShoemakerFt. Lauderdale, FL
Abstract
Equivalent continuum, single-porosity models can provide reasonable volume-averaged approximations of large-scale karstic ground-water flow, but concentrated, near-field flow within preferred stratiform pathways is poorly represented. The outcome of a tracer test at the Miami-Dade County Northwest well field shows that effective porosity between the point of injection and a production well ranges between 2-4%, an order of magnitude less than estimates based on specific yield equivalency assumptions. An existing well-field protection model assumes 20% effective porosity, whereas estimates of matrix total helium porosity are as much as 50% based on measurements of 3.4- and 4-inch diameter cores.
The U.S. Geological Survey is developing a Conduit Flow Process (CFP) for MODFLOW-2000 based on pipe-flow theory. Laminar and turbulent ground-water flow will be explicitly represented within a conduit network of tortuous pipes having internal roughness. The conduit network also will exchange ground water with a continuum porous-media matrix that provides most of the storage. The CFP will allow users to simulate multi-pore flow systems, such as the triple-porosity Biscayne aquifer, more realistically than is presently possible.